Design and implementation of 3.5 kva solar energy system for the department of electrical electronic engineering, Nigerian Defence Academy Department:Electrical Electronics Engineering By: abdul6ix9ine Project ID: 7119 Rating: (5.0) votes: 1 Price:₦4000 Get the Complete MaterialAbstractThis research work deals with the Design and Implementation of 3.5 kVA Solar Energy System for the Department of Electrical/Electronic Engineering, Nigerian Defence Academy. The optimal tilt angle and orientation for the installation of the photovoltaic (PV) panels in the location under consideration were determined. This was achieved by varying the tilt angle from 3.1o to 37.2o at a succession of 3.1o between the hours of 7:00 am and 6:00 pm for a period of ten days. The equipment of the solar energy system were adequately sized using the required mathematical models. MATLAB software was comprehensively utilized in performing the various analyses. The optimal tilt angle and orientation for the PV panel after analysis for which optimum power harvest was attained, was found to be 24.8o and south respectively. Based on the load demand, a total battery capacity of 4235 Ah was obtained. Also, PV, charge controller and inverter ratings of 254.10 A, 10.51A and 3.85 kVA were also obtained respectively. The power output of a PV panel depends on the tilt angle, orientation and weather conditions. An accurate solar energy installation could lead to a lower power harvest which has a negative impact on the entire system. ...Preview Download Preview +Other Electrical Electronics Engineering project topics and materials you might be interested in»The construction of a 2kva automatic voltage regulator (AVR)»Generation of Constant Power Supply from a DC Source»Design and construction of a digital clock with calendar»Construction of digital AC power controller»A remote controlled AC fan speed regulator using discrete integrated circuit»Remote controlled antenna»The construction of automatic voltage inverter and a battery charger»Design of 2.5kw automatic voltage regulation with seven segment display»Simple sensitive touch alarm»Construction of a car touch intruder alarm»Design and construction of 2KVA inverter»Design and construction of 5kva power inverter»Design and installation of 200 WATT solar power system»Design and construction of an automatic change over switch»Construction of a battery charger